[ MDS 4710 ] [ MDS OEM ] [ entraNet 2400 ] |
|
|
|
MDS entraNet 2400 Data Radio |
|
|
|
Physical Dimensions
· 143(W)mm x 50(H)mm x 184(D)mm
Power Supply Requirement
· 10.5 to 16Vdc
· Rx Supply Current - < 125mA
· Tx Supply Current - 2A Typical at 5Watt
· Power Output adjustable 0.1 – 5 Watt
Data Interface
· RS-232 through DB-25 Connector
· Baud Rates Supported at Interface Port: 1200, 2400, 9600, 19200,
38400 bps
· Data Latency < 15 ms typical
General
· Frequency - 330 to 512MHz with 6.25KHz increments to any MAS
channel pair
· Temperature Range – 60oC to -30oC
· Humidity – 0 to 95% @ 40oC
· Data Performance - BER 1 x 10-6 @ -113dBm typical
· Duty Cycle - Continuous
· Key-Up time - 2ms
· Baud Rate - 4800bps
· Operational Modes - Simplex, half-duplex
· Keys on data
· Key line output for keying external devices on receive
· Configures via HHT, MDS Configuration
Applications
· Gas/Oil Production and Distribution
· Water, Gas and Electric Utilities
· Lotteries
· Traffic Control
· Industrial Process Control
· Railroad Communication System |
|
|
|
|
|
|
|